Grease separator LipuJet-P-OD extension stage 1

Product benefits

  • With two inspection windows for sludge and grease control
  • Optionally with filling device
  • Optionally with grease level sensor

Product information

  • Grease separator according to EN 1825 for installation inside frost-free rooms
  • Manufactured of polyethylene in oval shape
  • Two covers odour-proof ∅ 450 mm
  • Inlet and outlet ∅ 200 mm (NS 15 – 25) or ∅ 250 mm (NS 30)
  • Two inspection windows with wiper
  • Operating side left or right
Item

number
Nominal capacityDimensions
L1H1H2H3H4W2
[mm][mm][mm][mm][mm][mm]
3815.45.42NS 15270018501640130012301340
3820.45.42NS 20340018501640130012301340
3825.45.42NS 25410019501740130012301340
3830.45.42NS 30480019501740130012301340
3815.45.32NS 15270018501640130012301340
3820.45.32NS 20340018501640130012301340
3825.45.32NS 25410019501740130012301340
3830.45.32NS 30480019501740130012301340

Grease layer thickness measuring device

Image
Suitable for
  • LipuJet-P
    • Oval NS 1 – 10
    • Round NS 2 – 20
  • LipuJet-S
    • Oval NS 1 – 10
    • Round NS 2 – 20
  • LipuSmart-P
    • Oval NS 1 – 10
Description
  • For electronic measurement of layer of grease
  • Suitable for liquid and/or congealing grease
  • Measuring device with plug and used connecting cable, length: 3 m
  • With two voltage-free changeover contacts to display full warning (80%) and advance warning of fill level (50%)
  • With visual display of fill level
  • With heated probe rod to increase reliability of operation
  • Operating voltage: 230VAC/5 VA
  • Max consumption approx. 12W
  • Weight: 2.8 kg

Inlet valve DN 250

Image

Grease layer thickness measuring device Multi Control

Image
Suitable for
  • LipuJet-P
    • Oval NS 1 – NS 30
    • Round NS 2 – NS 20
  • LipuJet-S
    • Oval NS 1 – NS 10
    • Round NS 2 – NS 20
  • LipuSmart-P
    • Oval NS 1 – 10
Description
  • To determine the disposal intervals of grease separators
  • Suitable for liquid and/or harden fats
  • Delineation with colour-touchpanel
  • With integrated SD-card (4GB) for recording of the measuring process
  • With headed sounding stick (temperature is adjustable) to increase the operation safety
  • Three free of potential contacts for outoput of pre-alarm (adjustable), full-alarm (adjustable) and error
  • Measuring stick with adjusting scale
  • Delineation with plug-in cable connection, 3 m
  • Service voltage: 100 240VAC 50/60 Hz, 2 A
  • Power: ca. 43 W
  • Weight: 2.7 kg

Heating rod

Image
Suitable for
  • Grease separators
Description
  • To liquefy grease layer
  • Incl. control
  • Electrical connector
    • 400 V/50 Hz/6.0 kW
  • Weight: 15 kg

Filling device

Image
Suitable for
  • Grease separator
    • LipuJet-P-OB/OD/R/RD
    • LipuSmart-P-OB/OD
  • BioJet-P-OM/RM (NS 2-25)
Description
  • Free outlet as per DIN 1988 Part 4
  • For connection to drinking water supply
  • With DVGW / KIWA approval and inclined valve R ¾ "
  • With pressure relief valve with dirt trap
  • Weight: 3.5 kg

Sampling pot DN 200

Image
Suitable for
  • Grease separator LipuJet-P
    • NS 15 – 20
Description
  • For installation of horizontal pipes DN 200 to grease separator
  • Round shape with
    • Coupling socket seal (material SBR) on inlet and spigot on outflow
    • Odour-proof maintenance opening DN 450
  • Weight: 10.3 kg

Sampling pot DN 200

Image
Suitable for
  • Grease separator LipuJet-P
    • NS 15 – 20
Description
  • For installation in vertical pipes DN 200 going to grease separator
  • Round shape with
    • Coupling socket seal (material SBR) on inlet and spigot on outflow
    • Odour-proof maintenance opening DN 450
  • Weight: 10.2 kg

Coarse trap DN 200

Image
Suitable for
  • Grease separator LipuJet-P
    • NS 15 – 20
Description
  • For installation in vertical pipes DN 200 going to grease separator
  • Round shape with
    • Coupling socket seal (material SBR) on inlet and spigot on outflow
    • Basket made from stainless steel, material grade 316 to retain coarse substances
    • Odour-proof maintenance opening DN 450
  • Weight: 9.9 kg

Sampling pot DN 250

Image
Suitable for
  • Fettabscheider LipuJet-P
    • NS 30
Description
  • Weight: 18 kg

Sampling pot DN 250

Image
Suitable for
  • Fettabscheider LipuJet-P
    • NS 30
Description
  • Weight: 18 kg

Coarse trap DN 250

Image
Suitable for
  • Fettabscheider LipuJet-P
    • NS 30
Description
  • Weight: 23 kg

Connection box

Image
Suitable for
  • Grease separators
    • LipuMax-P-D/DM/DA
    • LipuJet-P-OD/RD/SD/OM/OMP/RM/RMP
    • LipuJet-S-OD/RD/SD/OM/OMP/RM/RMP
  • Stach seperators FapuMax-P-DA
  • Oil separators Coalisator-P
Description
  • For evacuation connection DN 80
  • Made from stainless steel, material grade 304
  • "On wall" version
  • Door stop
    • Choice of left or right
    • Lockable door
  • Dimensions (width x height x depth): 370 x 330 x 250 mm
  • Weight: 10.4 kg

In-wall frame

Image
Suitable for
  • Connection box
    • 7601.80.22
Description
  • Stainless steel, material grade 304
  • Dimensions (width x height x depth): 421 x 381 x 25 mm
  • Weight: 1 kg

PIPE connection set ND 200 for Grease Separators

Image
Suitable for
  • Grease separator LipuJet for free-standing installation
    • NS 15-25
Description
  • For connection of the grease separator feed line
  • From stainless steel, material grade 316 L
  • EPDM seal
  • DN 200
  • 2 x bends 45°
  • 1 x intermediate piece 500 mm
  • 1 x calm region 2000 mm
  • Weight: 25 kg

Smell neutralisation

Image
Suitable for
  • Grease separators (incl. external makes)
Description
  • Lockable control cabinet
    • From stainless steel, material grade 304
    • Ground surface
    • With side ventilation slots
  • Integrated timer
  • Incl. odour neutralisers: 9 l
  • With dosing pump for reliable discharge
  • Chemical resistant dosing hose
  • Signal column for status monitoring
  • PG gland for on-site connection
  • Control cabinet dimensions: 380 x 600 x 210 mm (W x H x D)
  • System ready to plug in
    • Incl. cable: 1.5 m
  • 230 V socket to be produced on-site
  • Weight: 36.2 kg

Service grease separator: commissioning

Image
Suitable for
  • ACO grease separator for free-standing installation
Description

Commissioning includes the following services:

  • Arrival and removal including working hours, which do not exceed the scope of the commissioning
  • Installation check
  • Electrical testing
  • Mechanical testing
  • System parameterisation
  • Multiple trial runs
  • Operating personnel induction
  • Creation of a commissioning checklist

Upon conclusion of an original ACO maintenance contract, the costs of

commissioning will be offset with the first maintenance service!

Further information: ACO Service 036965/ 819-444

Service grease separator: maintenance

Image
Suitable for
  • ACO grease separator for free-standing installation
    • One contract per grease separator
Description
  • Maintenance in accordance with the checklist based on EN 1825-2 when concluding a maintenance contract with ACO Building Drainage.
  • Separator systems should be maintained by an authorised qualified contractor
  • The maintenance interval should not be longer than 1 x year.

The maintenance service includes the following work:

  • Arrival and removal including working hours, which do not exceed the scope of the maintenance
  • Checking internal wall surfaces
  • Functional check on electrical equipment, if available
  • Checking the entire system with the creation of a test report and, if necessary, a repair offer

A disposal vehicle should be available at the time of maintenance.

Further information: ACO Service 036965/ 819-444

Service grease separator: General inspection

Image
Suitable for
  • ACO grease separator for free-standing installation
Description

According to DIN 4040-100, separator systems must be checked before commissioning and then at regular intervals of a maximum of 5 years after full emptying.

Testing takes place according to EN 1825 / EN 1610.

Our report includes the exact description of the system with measurement, measurement graphics and image documentation, as well as suggestions for further procedures (defect elimination).

The following preparations must be made on-site before the general inspection:

  • Free access for all vehicles
  • Full installation of the system
  • Electrical connection 230V
  • The system must be emptied and clean at the time of testing
  • The possibility of quick water filling is required (supply of fresh water by the disposer or C-connection)
  • An assistant will be provided to us free-of-charge for the work
  • You shall provide climbing aids (ladders)
  • The contents of the separator must be disposed of on the day of the general inspection! Disposal is ordered by the customer, unless otherwise expressly agreed.
  • For the duration of the General Inspection, no inlet into the separator may take place for approx. 4-5 hours

Further information: ACO Service 036965/ 819-444