Lipumax G-DM

Product benefits

  • Simple to install, requires less space
  • Top section with odour proof sealed cover
  • Integrated connection for sampling device
  • Including rubber seal ring for connection with cover plate

Product information

  • Tank made of glass reinforced plastic
  • With integrated sludge trap
  • One-piece construction
  • Inner parts made of PEHD
Item

number
Nominal sizeDimensions
H1H2D1D2T tank
[mm][mm][mm][mm][mm]
12502.032 NS84577510001246445
12509.032 NS1180111010001246445
12503.034 NS1130106010001246495
12510.034 NS1395132512001434535
12504.037 NS1395132512001434535
12511.037 NS1630156015001759635
12505.0310 NS1360129015001759635
12512.0310 NS1925185515001759635
12515.0315 NS1410134018002014845
12513.0315 NS2000193018002014845
12517.0320 NS1610154018002014845
12516.0320 NS2395232518002014845
12518.0325 NS1745167522002455795
12514.0325 NS2445237522002455795

Lipumax G-D (Extension stage 1)

  • Odour-free disposal via a connector to direct suction
  • After-cleaning by opening the cover (associated with the slight formation of noxious smells)
  • Disposal connection DN65 (flange 75)
Lipumax G-D

Lipumax G-DM (Extension stage 2)

  • Manual odour-free disposal/cleaning via direct suction and hydro-mechanic high-pressure inner cleaning
  • Disposal connection DN65 (flange 75)
  • Filling device with ball valve for re-filling with fresh water
  • Hydro-mechanic inner cleaning via high-pressure pump and spray head

Lipumax G-DA (Extension stage 3)

  • Programmed, odour-free disposal/cleaning via direct suction and hydro-mechanic high-pressure inner cleaning
  • Disposal connection DN65 (flange 75)
  • Filling device with soleniod valve for re-filling with fresh water
  • Hydro-mechanic inner cleaning via high-pressure pump and spray head
Lipumax G-DA

ACO Belt 75 SS

Suitable for

7,5 m

Description
  • Load strap: Polyester
  • Tensioner and hooks: Stainless steel
  • Package includes 2 pcs of anchors T10/150SS
  • Usage for tanks dia ≤ 2.57 m

ACO Belt 120 SS

Suitable for

12 m

Description
  • Load strap: Polyester
  • Tensioner and hooks: Stainless steel
  • Package includes 2 pcs of anchors T10/150SS
  • Usage for tanks dia ≤ 2.57 m

Control unit GA 1 + one sensor GA - SG1

Suitable for

GA-1 is an alarm device specially designed for grease separators. They indicate when it is time to empty the grease separator and thus prevents harmful grease emissions to the sewer system.

Description
  • Dimensions: 125 mm x 75 mm x 35 mm (L x H x D
  • Material: Polycarbonate
  • Enclosure: IP65
  • Operation temperature: -30 °C...+50 °C
    • Supply voltage: 230 VAC ± 10 %, 50/60 Hz
    • The device is not equipped with a mains switch
    • Power consumption: GA-1: 5 VA, GA-2: 5 VA
    • Sensors: 1 or 2 GA-SG1 sensors
    • Relay outputs: Potential-free relay output 250 V, 5 A
    • 1 pcs for GA-1 Operational delay 10 sec. Relay de-energize
    • 2 pcs for GA-2 at trigger point.
    • Electrical safety: IEC/EN 61010-1, Class II , CAT II
    • EMC: IEC/EN 61000-6-3 (Emission)
    • IEC/EN 61000-6-1 (Immunity)

Control unit GA 2 + two senzors GA - SG1

Suitable for

GA-2 is an alarm device for monitoring the thickness of the grease layer accumulating in a grease interceptor and the blocking of the interceptor. The system consists of a GA-2 control unit, two GA-SG1 sensors and a cable joint.

Description
  • Dimensions 125 mm x 75 mm x 35 mm (L x H x D)
  • Package 1,2 kg (control unit + 2 sensors + cable joint)
  • Enclosure IP 65, material polycarbonate
  • Cable glands adjustment range 6-10 mm
  • Operation temperature -30 ºC...+50 ºC
    • Supply voltage 230 VAC ± 10 %, 50/60 Hz
    • The device is not equipped with a mains switch
    • Power consumption 5 VA
    • Sensors 2 pcs GA-SG1 sensors
    • Relay output 2 pcs potential-free relay outputs
    • 250 V, 5 A Operational delay 10 sec.
    • Relay de-energize at trigger point.
    • Electrical safety IEC/EN 61010-1, Class II , CAT II
    • EMC Emission IEC/EN 61000-6-3
    • Immunity IEC/EN 61000-6-1

Control and alarm unit holder

Suitable for

Complementary for all alarm devices and control units