Lipumax G-D

Nominal capacitySludge trapDimensions
DHH1H2
[l][mm][mm][mm][mm]
NS 11001101180740670
NS 22001101310870800
400110156011201050
NS 4400160161011201050
800160189013301260
NS 7700160194013801310
1400160224016001530
NS 101000160200013801310
2000200263519951925
NS 151500200222014301360
3000200280020101940
NS 202000200241016201550
4000200320524052335
NS 252500250235015601490
5000250301022202150

ACO Belt 75 SS

Suitable for

7,5 m

Description
  • Load strap: Polyester
  • Tensioner and hooks: Stainless steel
  • Package includes 2 pcs of anchors T10/150SS
  • Usage for tanks dia ≤ 2.57 m

ACO Belt 120 SS

Suitable for

12 m

Description
  • Load strap: Polyester
  • Tensioner and hooks: Stainless steel
  • Package includes 2 pcs of anchors T10/150SS
  • Usage for tanks dia ≤ 2.57 m

Control unit GA 1 + one sensor GA - SG1

Suitable for

GA-1 is an alarm device specially designed for grease separators. They indicate when it is time to empty the grease separator and thus prevents harmful grease emissions to the sewer system.

Description
  • Dimensions: 125 mm x 75 mm x 35 mm (L x H x D
  • Material: Polycarbonate
  • Enclosure: IP65
  • Operation temperature: -30 °C...+50 °C
    • Supply voltage: 230 VAC ± 10 %, 50/60 Hz
    • The device is not equipped with a mains switch
    • Power consumption: GA-1: 5 VA, GA-2: 5 VA
    • Sensors: 1 or 2 GA-SG1 sensors
    • Relay outputs: Potential-free relay output 250 V, 5 A
    • 1 pcs for GA-1 Operational delay 10 sec. Relay de-energize
    • 2 pcs for GA-2 at trigger point.
    • Electrical safety: IEC/EN 61010-1, Class II , CAT II
    • EMC: IEC/EN 61000-6-3 (Emission)
    • IEC/EN 61000-6-1 (Immunity)

Control unit GA 2 + two senzors GA - SG1

Suitable for

GA-2 is an alarm device for monitoring the thickness of the grease layer accumulating in a grease interceptor and the blocking of the interceptor. The system consists of a GA-2 control unit, two GA-SG1 sensors and a cable joint.

Description
  • Dimensions 125 mm x 75 mm x 35 mm (L x H x D)
  • Package 1,2 kg (control unit + 2 sensors + cable joint)
  • Enclosure IP 65, material polycarbonate
  • Cable glands adjustment range 6-10 mm
  • Operation temperature -30 ºC...+50 ºC
    • Supply voltage 230 VAC ± 10 %, 50/60 Hz
    • The device is not equipped with a mains switch
    • Power consumption 5 VA
    • Sensors 2 pcs GA-SG1 sensors
    • Relay output 2 pcs potential-free relay outputs
    • 250 V, 5 A Operational delay 10 sec.
    • Relay de-energize at trigger point.
    • Electrical safety IEC/EN 61010-1, Class II , CAT II
    • EMC Emission IEC/EN 61000-6-3
    • Immunity IEC/EN 61000-6-1

Control and alarm unit holder

Suitable for

Complementary for all alarm devices and control units

TOP