LipuLift-PF-B Basis

Product benefits

  • Separator, sampling and pump station in one housing
  • No piping between the components necessary
  • Only one plant control
  • Optimal air exchange due to interruption of the partition wall between separator and pump station
  • High effective volume of the pumping station for low pump wear
  • Four comfort stages possible

Product information

  • Grease separator according to EN 1825-1 made of polyethylene for underground installation with integrated dual pumping station according to EN 12050
  • Flexible version for variable inlet inverts
  • Two dome openings, each to accommodate a top section with covers according to either class A, B or D
  • Integrated pumping station according to EN 12050, accessible via the manhole cover
    • Pressure connection: 2 "- OD Ø 63 mm (PE pipe)
    • Ball backflow preventer
    • Voltage: 400 V, 50 Hz, speed: 2900 rpm
    • Protection class IP 68; Operating mode: 51
  • Disposal and cleaning via the manhole cover

Infobox

Buoyancy protection

  • Load class A15 and B125
    • Container buoyancy-proof from the container bottom up to a height of 1,650 mm (load class A15 and B125) with on-site concrete slab
  • Load class D400
    • Container buoyancy-proof from the container bottom up to a height of 1,650 mm (load class D400) with a concrete load distribution plate to be created on site

Please note

  • For the functionality of the pumping station, you can choose between a dynamic pressure bell (0155.41.90) or a pressure sensor (0178.63.87 or 0178.63.88)
Nominal sizeNominal widthContentsKey data pump unitItem

number
DownloadsRemember
Sludge trapGrease storeOverallTypeUsable volumeDelivery head
[l][l][l][l][m]
NS 4110 mm5903701260Sat-100/D66011.83204.30.01
NS 7160 mm7805501760Sat-100/D66011.83207.30.01
Sat-150/D66015.53207.30.02
NS 10160 mm10107102260Sat-150/D66015.53210.30.02
Sat‑200/D66017.53210.30.03
Nominal sizeNominal widthContentsKey data pump unitItem

number
Sludge trapGrease storeOverallTypeUsable volume
NS 4110 mm590 l370 l1260 lSat-100/D660 l3204.30.01
NS 7160 mm780 l550 l1760 lSat-100/D660 l3207.30.01
NS 7160 mm780 l550 l1760 lSat-150/D660 l3207.30.02
NS 10160 mm1010 l710 l2260 lSat-150/D660 l3210.30.02
NS 10160 mm1010 l710 l2260 lSat‑200/D660 l3210.30.03
Nominal sizeDimensions
L1L2H1
[mm][mm][mm]
NS 4277015001125
NS 7326019901100
NS 10375024801100
Characteristic curve
TypeDelivery headDelivery flow Q with overall delivery head HMedia temperature
2 m4 m6 m8 m10 m12 m14 m16 m18 mNormalMaximum
[m][l/s][l/s][l/s][l/s][l/s][l/s][l/s][l/s][l/s][°C][°C]
Sat-100/D2 – 11.89.58.57.35.94.01.04065
Sat-100/D
Sat-150/D2 – 15.511.911.110.08.87.55.93.70.74065
Sat-150/D
Sat‑200/D2 – 17.513.012.111.310.49.27.75.93.50.84065
Image

compression bell

Image
Suitable for
  • LipuLift-P
  • LipuLift-PF
Description
  • Dynamic pressure bell for switching the pump technology via a pneumatic measuring hose with air bubble injection
  • Tube length: 20 meter
  • Attention! Laying must be carried out without kinks, rising to the switching device

Pressure pick-up

Image
Suitable for
  • Control ACO Multi-Control Mono/Duo
  • LipuLift-P/LipuLift-PF
Description
  • 4–20 mA
  • For secure switching cable lengths > 12 m
  • 0–200 mbar
  • With cable for installation: 20 m
  • Weight: 2 kg

Pressure pick-up

Image
Suitable for
  • Control ACO Multi-Control Mono/Duo
  • LipuLift-P/LipuLift-PF
Description
  • 4–20 mA
  • For secure switching cable lengths > 12 m
  • 0–200 mbar
  • Cable for installation: 40 m
  • Weight: 3.4 kg

Signalling unit

Image
Suitable for
  • Faecal matter backflow automatic stop Quatrix-K type 3F
  • All Muli wastewater lifting plants
  • Upstream tank plant mono/duo
  • Muli-Max
  • Sinkamat –K/-KD
  • Sinkamat-Z
  • Sinkamat-Z (underfloor)
    • Duo
  • LipuLift-P
Description
  • Self-charging
  • With floating contact
  • Visual and acoustic
  • Without contact transmitter
  • For mounting outside the potentially explosive atmosphere
  • Dimensions: 175 x 125 x 75 mm W x H x D
  • Protection type: IP65
  • Operating voltage: 230 V/AC 50/60 Hz
  • Ready to plug in with cable: 2 m
  • Weight: 1.4 kg

Message system with GSM module

Suitable for
  • Faecal matter backflow automatic stop Quatrix-K type 3F
  • All Muli lifting plants
  • Muli-Max
  • Sinkamat-Z (underfloor) duo
  • Grease separators
  • Measuring device for grease layers
  • Wet refuse collection systems
  • Technical processing systems
Description
  • Does not require mains power
  • Visible and audible alarms
  • 6 digital & 2 analogue freely configurable inputs
  • 1 alarm output 12V
  • Incl. GSM- aerial (2,5m wire)
  • Relaying alarms to mobile phones by SMS
  • For mounting outside the ex-area
  • Housing: 155x180 x103 mm
  • Slot for standard SIM-card
  • Protection level: IP54 (with fitted IP44 antenna socket)
  • Operating voltage: 230 V/AC 50/60 Hz
  • Weight: 2 kg

Grease layer thickness measuring device Multi Control

Image
Suitable for
  • Grease separator LipuMax-P, LipuLift-P for underground installation
Description
  • To determine the disposal intervals of grease separators
  • Suitable for liquid and/or harden fats
  • Delineation with colour-touchpanel
  • With integrated SD-card (4GB) for recording of the measuring process
  • With headed sounding stick (temperature is adjustable) to increase the operation safety
  • Three free of potential contacts for outoput of pre-alarm (adjustable), full-alarm (adjustable) and error
  • Measuring stick with adjusting scale
  • Delineation with plug-in cable connection, 3 m
  • Service voltage: 100 240VAC 50/60 Hz, 2 A
  • Power: ca. 43 W
  • Cable length: 10 m
  • Weight: 6.5 kg

Grease layer thickness measuring device Multi Control

Image
Suitable for
  • Grease separator LipuMax-P, LipuLift-P for underground installation
Description
  • To determine the disposal intervals of grease separators
  • Suitable for liquid and/or harden fats
  • Delineation with colour-touchpanel
  • With integrated SD-card (4GB) for recording of the measuring process
  • With headed sounding stick (temperature is adjustable) to increase the operation safety
  • Three free of potential contacts for outoput of pre-alarm (adjustable), full-alarm (adjustable) and error
  • Measuring stick with adjusting scale
  • Delineation with plug-in cable connection, 3 m
  • Service voltage: 100 240VAC 50/60 Hz, 2 A
  • Power: ca. 43 W
  • Cable length: 20 m
  • Weight: 7.8 kg

Grease layer thickness measuring device Multi Control

Image
Suitable for
  • Grease separator LipuMax-P, LipuLift-P for underground installation
Description
  • To determine the disposal intervals of grease separators
  • Suitable for liquid and/or harden fats
  • Delineation with colour-touchpanel
  • With integrated SD-card (4GB) for recording of the measuring process
  • With headed sounding stick (temperature is adjustable) to increase the operation safety
  • Three free of potential contacts for outoput of pre-alarm (adjustable), full-alarm (adjustable) and error
  • Measuring stick with adjusting scale
  • Delineation with plug-in cable connection, 3 m
  • Service voltage: 100 240VAC 50/60 Hz, 2 A
  • Power: ca. 43 W
  • Cable length: 30 m
  • Weight: 9.6 kg

Grease layer thickness measuring device

Image
Suitable for
  • Grease separator LipuMax-P for underground installation
  • LipuLift-P
Description
  • For electronic measurement of layer of grease
  • Suitable for liquid and/or congealing grease
  • Measuring device with plug and used connecting cable, length: 3 m
  • With two voltage-free changeover contacts to display full warning (100%) and advance warning of fill level (80%)
  • With visual display of fill level for advance warning and full warning
  • With heated probe rod to increase reliability of operation
  • Operating voltage: 230 V/50 Hz
  • Max consumption approx. 12W
  • Cable length: 10 m
  • Weight: 6.4 kg

Grease layer thickness measuring device

Image
Suitable for
  • Grease separator LipuMax-P for underground installation
  • LipuLift-P
Description
  • For electronic measurement of layer of grease
  • Suitable for liquid and/or congealing grease
  • Measuring device with plug and used connecting cable, length: 3 m
  • With two voltage-free changeover contacts to display full warning (100%) and advance warning of fill level (80%)
  • With visual display of fill level for advance warning and full warning
  • With heated probe rod to increase reliability of operation
  • Operating voltage: 230 V/50 Hz
  • Max consumption approx. 12W
  • Cable length: 20 m
  • Weight: 7.8 kg

Grease layer thickness measuring device

Image
Suitable for
  • Grease separator LipuMax-P for underground installation
  • LipuLift-P
Description
  • For electronic measurement of layer of grease
  • Suitable for liquid and/or congealing grease
  • Measuring device with plug and used connecting cable, length: 3 m
  • With two voltage-free changeover contacts to display full warning (100%) and advance warning of fill level (80%)
  • With visual display of fill level for advance warning and full warning
  • With heated probe rod to increase reliability of operation
  • Operating voltage: 230 V/50 Hz
  • Max consumption approx. 12W
  • Cable length: 30 m
  • Weight: 9.6 kg

Signal horn

Image
Suitable for
  • Signalling unit with voltage-free fault reporting
  • LipuSmart-P
  • Muli-Max with signalling unit
  • LipuLift-P
Description
  • 230V AC
  • Power consumption: 15mA
  • 172x70x78mm (LxBxT)
  • Protection: IP33
  • 92 dB(A)
  • Weight: 0.3 kg

Signal horn

Image
Suitable for
  • Signalling unit
  • Signalling unit with GSM module
Description
  • Operating voltage: 12V DC
  • Power consumption: 30 mA
  • 62 x 62 x 85 mm (LxWxD)
  • Degree of protection: IP66
  • Noise level: 95 dB(A)
  • Weight: 0.2 kg

Flashing light

Image
Suitable for
  • Signalling unit with voltage-free fault reporting
  • LipuSmart-P
  • Muli-Max with signalling unit
  • LipuLift-P
Description
  • 230V
  • Power consumption: 70 mA
  • Weight: 0.5 kg

Flashing light

Image

Outdoor cabinet for on-site pressure pipe

Image
Suitable for
  • GRP outdoor cabinet for on-site pressure line
    • DN 80
    • DN 100
    • DN 125
    • DN 150
,
  • LipuLift-P Serie
Description
  • With reserve space for installation of an on-site backflow loop according to DIN 12056-4 and 1986-100
  • With mounting plate incl. base
  • With heating and thermostat
  • With CEE32 and work socket with earth contact
  • Dimension: 2000 x 806 x 335 mm (H x W x D)
  • Weight: 100 kg

Outdoor cabinet

Image
Suitable for
  • Muli-Max
  • Powerlift–P
  • LipuLift-P-B/P-D
Description
  • As empty housing
  • Dimensions: 310 x 230 x 1,400 mm (L x W x H)
  • For installation for an on-site backflow loop in DN 50
  • With heated cabinet and thermostat, 230 V, 50 Hz
  • With mounting plate and safety lock
  • Weight: 13.8 kg

Outdoor cabinet

Image
Description
  • Dimensions: 310 x 1460 x 207 mm (H x W x D)
  • With pre-fuse C16 (16 A)
  • With 10 mm² PE-terminals for voltage compensation
  • Flashing light (knock resistant)
  • Closed using safety lock cylinder
  • Weight: 21.1 kg

Outdoor cabinet for local pressure pipes an controller

Image
Suitable for
  • Muli-Max
  • Powerlift–P
  • LipuLift-P-B/P-D
Description
  • Dimension: 2000 x 806 x 335 mm (H x W x D)
  • With reserve space for installation of an on-site backflow loop according to DIN 12056-4 and 1986-100
  • DN 50 – DN 200
  • With mounting plate incl. base
  • With lamp
  • With CEE32 and work socket with earth contact
  • With heating and thermostat
  • With security lock
  • Weight: 76 kg

Cable feedthrough ND 100

Image
Suitable for
  • LipuMax-P-B / D and LipuLift-P-B / D (only in the case of on-site fat layer measurement)
Description
  • Material: V4A
  • For simple and fast sealing of up to 5 cables
  • Seal against pressurised water
  • Interchangeable insert 2x5mm, 2x7mm, 2x16mm, 1x12mm, 1x14mm
  • Weight: 1 kg

Compression fitting 63 x 75 mm

Image
Suitable for
  • Powerlift installation kit DN 50
  • Powerlift–P
  • LipuLift-P
Description
  • Material: PP
  • Pressure level: PN16
  • For extending the pressure line diameter from Ø63 mm to Ø75 mm
  • Weight: 0.8 kg

Compression fitting 63 x 90 mm

Image
Suitable for
  • Powerlift installation kit DN 50
  • Powerlift–P
  • LipuLift-P
Description
  • Material: PP
  • Pressure level: PN16
  • For extending the pressure line diameter from Ø63 mm to Ø90 mm
  • Weight: 0.7 kg

Guide strap

Image
Suitable for
  • Top section
    • 0178.08.35
,
  • 2 Stk. bei LipuLift-P
Description
  • Quantity required
    • 1 pce for Muli-Max Mono
    • 2 pces for Muli-Max Duo
  • Weight: 1.6 kg

Operating key

Suitable for
  • LipuLift-PF
Description
  • Length 1735 mm
  • With chain

Operating Logbook

Suitable for
  • Grease separator
    • For underground installation
    • For free-standing installation
Description
  • Contents: Check-list and standard forms to document in-house monitoring, maintenance and disposal relating to the plant as required by DIN 4040-100
  • Format: A4 with double filing rings
  • Size: 60 pages
  • Laid out to cover 5 years
  • Weight: 0.3 kg